Customization: | Available |
---|---|
After-sales Service: | One Year Free Maintenance |
Warranty: | One Year Free Maintenance |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The temperature is controlled by PID/SSR, the control precision is high, the reflection is sensitive, and the output is stable.
2, Heat Insulation
Multi-fiber insulation cotton insulation, the solid casing is safe and reliable, and can maintain high temperature work for a long time.
3, Temperature Control SystemIntelligent digital display temperature adjustment, the air outlet is equipped with a temperature sensor, and the temperature can be adjusted as needed. The temperature is accurately controlled to ±2 °C, and the working temperature is 395 °C.
4,High Heat Exchange Efficiency
Ingenious wind tunnel design, the air passes evenly from the inside/outside of the spiral heating wire, the heat exchange is nearly 100%, the wind pressure loss is less, and the flow rate is less.
5, Safety
It is equipped with overheating overload protection and power-off protection device to ensure the safety of the equipment, no waste gas, environmental protection, and can be operated 24 hours a day.
Model | YH400F-252W |
Air outlet size | Diameter 50mm 25mm (round air outlet, optional) |
Insulation material | Double insulation cotton |
Heater name | Heating wire |
Heater power | 2 × 2KW (power adjustable) |
Heater power adjustment | Intelligent temperature regulation |
Heating wire life | 100,000 hours |
Temperature table | Digital control |
Digital control | ±2°C |
Blower | 50W |
Air volume | 198M3/H, the actual air volume is about 98M3/H |
Blower static pressure | 198pa |
Number of hot air outlets | 2 |
Air outlet direction | Pair blowing (arbitrary adjustment of tuy distance) |
Air volume rises | 350 ° C |
Bearing temperature | <395°C |
Power demand | 220V |
Machine power | 4100W |
Machine weight | 15KG |
Safety level | Ground wire |